Version History

2007-10-12: CANdito 2.5 SP1

Download

With Service Pack 1, the following changes become effective:

General:

  • Partial loading of windows displayed on multiple pages works correct now
  • Visibility of the undocked symbol explorer is assured
  • Fixed problem with Macros for Text To Speech
  • Fixed Problem with curve windows and more than 10 curves
  • Fixed partial loading of windows which were displayed on multiple pages
  • GUI harmonisation for CANditoFlash

Measurement:

  • Saving a measurement label list is possible even if no device is selected
  • Curves with one column and multiple rows are now always handled like array signals
  • The logging file of the write window is completely write when measurement stops

Calibration:

  • Indirect modified parameters that are in the measurment list, are not updated until their new value is downloaded to the ECU
  • KWP2000 on K-line: KW_Standard.dll now supports parameter calibration while measurement is running

Flash Programming:

  • Use seed&key dll when flashing via CCPflash.exe
  • Possibility to reduce STmin to speedup flashing
  • CCP/XCP: Unlock required protocol resources for flashing

Database Editor:

  • Sort order of the database explorer lists are saved individualy for each object type

Functions and Scripts:

  • Path of a script added to the Extras menu can be relative now
  • Measurement file signals can be directly accessed by functions to create virtual MDF signals
  • Usability of th function browser "Intellisense" improved

Communication Protocols:

  • Handle french keywords for memory segments in ASAP2 file
  • Full support of J1939 for CANalyzer/CANoe ASC logging files
  • Support of CAN DBC databases with multiple multiplexer signals
  • Support of all LIN message types of CANalyzer/CANoe BLF logging files
  • Fixed issue when importing A2L database which resulted in corrupt flash offsets

Data Management:

  • Improved handling of variant codded parameters of the current device (C&P, save as...)
  • Improvements in reading DCM and CVX file which contains parameters using a symbol conversion table
  • Improvement in loading variant coded maps with standard axis
  • Improvement in handling parameters with overlapping addresses in the save action

Offline analysis measurement files:

  • Improved signal selection from measurement files
  • A start time can be specified for importing of ASCII measurement files.
  • A time unit (factor) can be specified for importing of ASCII measurement files.
  • Command line option -M opens a measurement file without a signal selection dialog
  • The comment in created Diadem export files is checked for unsupported characters.
  • The first Application Text Object in an CANalyzer/CANoe BLF logging file is used as comment for the MDF file.
  • Measurement files loaded inside the measurement file manager are loaded permanently.

Diagnostic:

  • Fixed problem in CANape scripting regarding diagnostic response handles in case of mixed physical/functional addressing usage
  • Fixed problem with CANape scripting command DiagSendRequest() in case of raw messages if no diagnostic database is used
  • Performance improvement building the service tree of the diagnostic console window
  • Fixed problems regarding bit field handling of CANdela service parameters

Map Reader:

  • ELF mapfile reader supports bit structures correct now.

© 2006-2008 Vector Group

Add page to favorites