2008-02-26: CANdito 2.5 SP3

Download

Die folgenden Änderungen werden mit Service Pack 3 (Update auf 2.5 Build 30) wirksam, SP1 und SP2 sind enthalten:

General:

  • Unknown window types of configurations from higher application versions are ignored now. The configuration is read without an error.
  • Issue fixed in case of moving the global cursor in pause mode during measurement.
  • Issue fixed if moving an icon of the toolbar is cancelled with ESC.
  • Fix permanent redraw of the measurement configuration dialog if this dialog is placed on a second monitor left of the main monitor.
  • The file name of a CAN device logging file can be extended by the device name to get unique names.
  • Performance of the measurement configuration dialog for very large configurations improved.
  • There is a warning message if a project or a configuration from a higher application version is loaded.
  • Signals from measurement files can be displayed during measurement.
  • Issue with measurement configuration dialog fixed.

Function and Scripts:

  • Only save a description of the referenced global variables into the configuration.

Communication Protocols:

  • CAN Remote frames are logged as remote frames into the CAN device logging file.
  • Decrease Reconnect delay in Datalogger mode (when restarting measurement).

Offline analysis measurement files:

  • Merging of unsorted and write protected MDF files is possible now.
  • Merging of MDF files is possible too if the source MDF files have records with and without record identifiers.
  • Signal value comments of a measurement file are saved if the measurement file is replaced by another file using the command "Display from measurement file".
  • The automatic zooming of a graphic after inserting a file signal can be reverted with one click even multiple signals are inserted.
  • Import converter for CANcase XL Log logging files optionaly generates a signal for the SyncPulse events.
  • Import converter for Logging files support conversion rules from FIBEX databases.
  • Import converter for Logging files reports an error if a unsupported file format is selected.
  • Fixed issue of the Logging file import converter under Windows Vista.
  • The size limit of the label list input field of the ASCII export converter options is removed.
  • Issue fixed in case of saving measurement file signals using a measurement configuration.

Diagnostics:

  • Diagnostic Console: Checkbox for automatic parameter initialization disabled in case of ODX.
  • Diagnostic Console: Improvement of macro recording in case of requests with no response.
  • CANape API: Possibility to iterate through complex responses.
  • Fixed issues with automatic script creation (macro recording) for parameter value containing special character '%'.