Click here to download
General Improvements :
- Support of new linker map format Microsoft VC8
- Optional turn off acoustic feedback of multimedia signals before measurement is startet
- Save the configured view (sort order) of the measurement list
- Possibility to set the process priority during measurement.
- Usage measurement start time in the MDF file header of CANalyzer logging files (BLF)
- Value Block: Allow to copy value blocks with different dimension into another (MATRIX_DIM problem)
- New Function to open (execute) the menu items from scripts
- Align Virtual MDF signals to trigger
- New array index form 'array.0.0' in scripting language
- DBC Export for CANcaseXL Log: Support of CCP 1.01 and additional improvements
- Datalogger mode: Ignore INIT_RETRIES parameter.
Drivers / Interfaces:
- XCP: Support event channel priority
- XCP on LIN: Support XCP on LIN 1.3
- XCP on LIN: Support NAD to be part of IF_DATA
- XCP via Serial: Support of two or more serial ports
- Support of CRC-32 checksum with XCP
- NI-DAQmx: Support of cyclic data acquisition
Diagnostics:
- Diagnostic macro recording supports new qualifier syntax.
- Diagnostic: Displaying information in case of response parse error.
- Diagnostic: Display message in write window if Vector CAN hardware configuration has been changed
- Diagnostic: Display warning message if DiagSendRequest(request, SPR) is send and SPR isn't supported by that service
- Support measurement and calibration of diagnostic response and request parameters an case of ODX
- Diagnostic driver: Calibration windows and scripts consider the audience setting (user dependant set of diagnostic diagnostic functions)
- Enhanced diagnostic scripting to support functional addressing
Data Base Editor:
- Extended plausibility check for bitmasks in database editor
Other issues:
- Optimized redraw of graphic windows in scroll mode
- Destination folder can be selected for loading a zipped project
- Editing components of a record layout works correct now
- Bitmasks in ASAP2 file for non integer values are ignored now
- After changes in the database the view update works correct now
- Address extension input in database dialog is in HEX format now
- Assign multiple signals to a partial database (multi selection of signals )
- Settings of ATF import converter are saved now
- Proper handling of measurement mode filter in measurement list
- Correct verbal conversion rule is used now when adding enums from an IEEE map file
- Changing the input variable of an existing Matlab/Simulink model works correct now
- MDF Batch converter works also without sort flag now
- Symbol Explorer works correct now after replacing a huge MDF file in Measurement File Manager
- Counter macro in MDF File Path works correct now
- Map file directories different from current working directory work correct now
- Loading of parameters during measurement works correct now
- Selection/Focus in database editor is restored after changing the application
- Existing projects with large number of GDI objects can be loaded again
- Drag&Drop of signals from a graphic window to another page works correct now
- Filter dialogs in CDM-Studio work correct now
- Update problems in Calibration windows are solved
- Load of database on start of CDM-Studio
- Diagnostic Console: enhanced check of request service before submitting( Are the symbolic service parameter values are valid ? ).
- Take conversion rule for displaying signals from a file using the measurement objects from file.
- Proper notification in diagnostic console, if macro ended.
- New aliases for scripting functions( DiagGetDbName for DiagGetCddName and DiagGetVariant for DiagGetCddVariant ).
- Change dimension via interpolation denied if dimension is fix
- Using the block measurement mode, signals from ODT messages greater then 8 kB can be saved into MDF
- Close Write window during measurement enabled
- CCP: include SET_SESSION_STATUS command in CCP-DBC configuration
- KWPonCAN: Option to accept/ignore the A2L IFDATA settings without confirmation
- Graphic window: Support command "fit signals on top of each other" to common axis signals
- Improved handling of inconsistent CDDs
- FlexCard II is available in user interface
- XCP on LIN: CANape go online on starting project
- Measurement cursor should display values hexadecimal if the display use hexadecimal
- Multimedia window: Show live video after measurement

Contact