Download
General Usage:
- CANdito Flash: new dedicated utility intended for flash download by diagnostic script.
- Support of sorted search result in Symbol Explorer
- Proper size of popup menus
- Windows without frame can be resized to a very small size
- Save the last used file name filter of the measurement file selection dialog
- Proper handling of measurement mode "on key" of CANdito version 6.1.10
- Options Dialog: Explanation for "Increased realtime ability" enhanced
- Update a closed Symbol Explorer if he is opened again
- Panel window data link dialog enhanced
- Handling corrected in case of a project is loaded or CANdito is closed and the current project contains calibration or measurement comments
- Handling corrected in case of inserting a signal in Measurement list dialog if a database selection is open and a filter dialog is opened
Offline analysis measurement files:
- Possibility to merge mdf-files again that are previously splitted from another MDF file
- The import converter support CANcaseXL LOG logging files (XLG files)
- Delete temporary files of imported CANalyzer logging files, if the file device is permanent loaded
- The MATLAB export converter skips signals of datatype greater then 32 bit (doesn't abort any longer)
- The ATF Import converter creates MDF 3.0 files
- ASCII Import converter support values with more then 9 digits now
- Corrected generation of Float Signal definition with long names (caused syntax errors in generated dbc file (for logger daq measurements))
- CANalyzer Logging Converter is able to deal with BLF files including environment variables of type double
- Proper reading of negativ values of MOTOROLA signed integer signals (MDFlib++)
- Add a MDFlib++ function to read and modify the value raster item of a channel block
- All Files Filter *.* of the new Import Converter is included in the "All Measurement Files" Filter
- MDFlib++ supports DAT files (MDF format) created by ETAS Ascet SD
- Support a difference line time lower then the comment line time for Signal comments. Fix problem of the value macro in case of a Xoffset
- Improved support of M files created by the MATLAB export converter (syntactical problems fixed)
Display of measurement data:
- Inserting a curve without axis into an existing calibration window is possible
- Color of nearly white signals is adapted at print operation
- Correction of activity display of numeric measurement windows
- Command 'Save Signals' of a graphic window saved only data points inside the specified time range
- Print the name of a y axis of graphic windows on the printer
- Global measurement cursor is set to the previous position at stop of measurement
- Trigger times and signal comment times is adjusted during saving signals from a graphic window if time stamps start from zero
- Display improvements of Y axis labels in graphic windows if the window is too small
Database:
- Enhanced importing specific LIN databases
- Complete original database file name is used as device name if a device is created because dropping the database in CANdito
- Default signal attribute value in DBC files is used to set the precision of CAN signals for the whole database
Diagnostic:
- The 'read all identified DTCs' default request has been changed to '0xa9 0x81 0x12'
- Fixed problems regarding Intel byte order for diagnostics driver
- All functional groups of the whole network can be selected for a functional diagnostic device driver
- Enhanced state and error information is displayed in the fault memory window
- Improved error message in case functional groups are not available because of communication problem
- Fixed drag & drop handling of ODX databases in case the files are not in the working directory
- New XML-Scriptfunction to save embedded file containers from ODX-F file to the working directory (flash download use case)
- Correction of wording within diagnostics driver dialog (Regular -> Normal; Mode -> Scheme)
Functions and Scripts:
- New script function to create directories
- Close progressbar after calling ProgressBarClose()
- Changing a variable value in functions using unary operators (a++) is recognized as write operation now.
- Added new script function that allows to switch from physical to function addressing (and vice versa)
- Function sizeof() even works for MDF file signals which are not previously created
CANdito API:
- Menu command "Device | New from MCD3 server" is only enabled if the appropriate user rights exist are set.
- Now registry is checked for installed MCD3D servers on device creation
- Improved handling while connecting to a remote MCD3MC server (now checking availability)
- New CANditoAPI function to get the CANdito Version